Product Name£ºHigh Frequency Three Phase Online UPS
     
     Key Features

    ¡ô LCD High frequency sine wave online UPS

    ¡ô DSP digital control double conversion technology, Zero transfer time

    ¡ô Single Phase, adjustable VAC and HZ by panel

    ¡ô Wide input voltage and frequency range, support generator

    ¡ô Advanced Input PFC Technology 0.99

    ¡ô Self-testing and battery management function

    ¡ô Automatic battery charging while UPS off mode

    ¡ô Lightning, surge, Short Circuit and Overload Protection, Alarm or Silence Settable

    ¡ô Audible Noise <50dBA

    ¡ô SNMP, EPO, MBS, option

    ¡ô Physical Form: Tower Type

    ¡ô Industrial Type of UPS

     
     Technical Specifications
     

    Item

    Model

    XG6K

    Power rating

    VA / Watts

    6KVA / 6KW

    Input

    Normal Voltage

    220VAC

     

    Voltage Range

    110 ~ 280VAC

     

    Frequency Range

    40Hz ~ 70Hz

     

    Input Power Factor

    >0.99 (full load)

     

    Generator

    Support generator input(Generator rating¡Ý2*UPS rating )

    Output

    Nominal Voltage

    220/230/240 VAC

     

    Frequency

    50 ~ 60Hz ± 0.1%

     

    Waveform

    Pure Sine Wave

     

    Transfer Time

    0ms

     

    Voltage Distortion

    ¡Ü6%,Full RCD load

     

    Voltage Distortion

    ¡Ü2%,Full R load

     

    Overload Capacity

    In Line Mode: 102%-105% load, 30mins; 105%-125% load, 10mins; 125%-150% load, 30s; >150% load, 500ms

     

     

    In Battery Mode: 102% -105% load, 10mins; 105%-125% load, 1min; 125%-150% load, 10s; >150% load, 500ms

     

    Load Peak Ratio

    3:1 (max)

    Efficiency

    Line Mode

    Up to 95%

     

    Battery Mode

    Up to 94%

     

    ECO Mode

    Up to 98%

    Battery

    Battery Type

    Sealed lead acid maintenance free

     

    Backup Time

    At least 15 minutes backup time at 50% (3000W) at full load

     

    Battery Voltage

    192-240VDC adjustable

     

    Charge Current

    1-12A settable

    Display

    LED Display

    Line, Inverter, Bypass, Battery

     

    LCD Display

    LCD For input output HZ/VAC, Bat %/VDC, Load % and VA/Watts, Temp. Fault Code, LED for line, battery, Inverter, Bypass, Fault

    Audible Alarm

    Battery Mode

    Beeping every 4 seconds (re-settable) and every second when battery low

     

    Overload

    Beeping twice every second

     

    Fault

    Beeping Continuously

     

    Battery Low/Charger Fault

    Beeping every 1 second

     

    Bypass Mode

    Beeping every 2 min

     

    L/N Inverse

    Beeping every 2 min

    Communications

    Interface

    RS232 Port x 1, USB Port x 1 and Smart Slot x 1

    Working Environment

    Operating Altitude

    1000 meters (without de-rating)

     

    Operating Temperature

    0°C ~ 40°C

     

    Storage Temperature

    -15°C ~ 50°C

     

    Relative Humidity

    0-95% (non-condensing)

    Product Size

    W x D x H (mm)

    260*533*560


     
     

    Tel: 0086-574-88216630    Fax: 0086-574-8813 8440    Email: kema@kemapower.com
    Factory:H/Block Beiyue Industrial Zone,Foshan,China.
    Ningbo office:R505-1,TAIKANG MIDDLE ROAD 468#,YINZHOU DISTRICT, NINGBO,CHINA