Product Name£º | High Frequency Three Phase Online UPS |
¡ô LCD High frequency sine wave online UPS
¡ô DSP digital control double conversion technology, Zero transfer time
¡ô Single Phase, adjustable VAC and HZ by panel
¡ô Wide input voltage and frequency range, support generator
¡ô Advanced Input PFC Technology 0.99
¡ô Self-testing and battery management function
¡ô Automatic battery charging while UPS off mode
¡ô Lightning, surge, Short Circuit and Overload Protection, Alarm or Silence Settable
¡ô Audible Noise <50dBA
¡ô SNMP, EPO, MBS, option
¡ô Physical Form: Tower Type
¡ô Industrial Type of UPS |

|
Item |
Model |
XG6K |
Power rating |
VA / Watts |
6KVA / 6KW |
Input |
Normal Voltage |
220VAC |
|
Voltage Range |
110 ~ 280VAC |
|
Frequency Range |
40Hz ~ 70Hz |
|
Input Power Factor |
>0.99 (full load) |
|
Generator |
Support generator input(Generator rating¡Ý2*UPS rating ) |
Output |
Nominal Voltage |
220/230/240 VAC |
|
Frequency |
50 ~ 60Hz ± 0.1% |
|
Waveform |
Pure Sine Wave |
|
Transfer Time |
0ms |
|
Voltage Distortion |
¡Ü6%,Full RCD load |
|
Voltage Distortion |
¡Ü2%,Full R load |
|
Overload Capacity |
In Line Mode: 102%-105% load, 30mins; 105%-125% load, 10mins; 125%-150% load, 30s; >150% load, 500ms |
|
|
In Battery Mode: 102% -105% load, 10mins; 105%-125% load, 1min; 125%-150% load, 10s; >150% load, 500ms |
|
Load Peak Ratio |
3:1 (max) |
Efficiency |
Line Mode |
Up to 95% |
|
Battery Mode |
Up to 94% |
|
ECO Mode |
Up to 98% |
Battery |
Battery Type |
Sealed lead acid maintenance free |
|
Backup Time |
At least 15 minutes backup time at 50% (3000W) at full load |
|
Battery Voltage |
192-240VDC adjustable |
|
Charge Current |
1-12A settable |
Display |
LED Display |
Line, Inverter, Bypass, Battery |
|
LCD Display |
LCD For input output HZ/VAC, Bat %/VDC, Load % and VA/Watts, Temp. Fault Code, LED for line, battery, Inverter, Bypass, Fault |
Audible Alarm |
Battery Mode |
Beeping every 4 seconds (re-settable) and every second when battery low |
|
Overload |
Beeping twice every second |
|
Fault |
Beeping Continuously |
|
Battery Low/Charger Fault |
Beeping every 1 second |
|
Bypass Mode |
Beeping every 2 min |
|
L/N Inverse |
Beeping every 2 min |
Communications |
Interface |
RS232 Port x 1, USB Port x 1 and Smart Slot x 1 |
Working Environment |
Operating Altitude |
1000 meters (without de-rating) |
|
Operating Temperature |
0°C ~ 40°C |
|
Storage Temperature |
-15°C ~ 50°C |
|
Relative Humidity |
0-95% (non-condensing) |
Product Size |
W x D x H (mm) |
260*533*560 |
    |
|
|