Product Name: | High Frequency Online UPS XG1-3K(S) Series |
|
◆ LCD High frequency double conversion sine wave online UPS1K 2K 3KVA
◆ DSP digital control technology, Zero transfer time
◆ Single phase sine wave, output Power Factor 0.8/0.9
◆ Wide input voltage range 115-300V(220V) or 60-138V(110V)
◆ Wide input Frequency 40-60HZ , support Generator,output HZ be fixed or follow mains
◆ Advanced Input PFC technology, 0.99
◆ Self-testing, ECO and Advanced battery management function
◆ Automatic battery charging while UPS off mode
◆ Lightning and surge protection, Short circuit and overload protection
◆ RS232 or USB communication with monitoring software
◆ SNMP, EPO option |
|
Item |
Model |
XG1K/1KS |
XG2K/2KS |
XG3K/3KS |
Capacity |
VA / Watts |
1KVA / 0.8KW or 0.9KW |
2KVA / 1.6KW or 1.8KW |
3KVA / 2.4KW or 2.7KW |
input |
Normal voltage |
220VAC or 110VAC |
Turn on Voltage range |
(90±5~300±5)VAC or ( 60~138)VAC |
Frequency range |
40~60Hz(adjustable) |
40~60Hz(adjustable) |
40~60Hz(adjustable) |
Input power factor |
0.99(220VAC,full R load) |
Generator |
Support generator input(Generator rating≥2*UPS rating ) |
line low loss/comeback |
220VAC:(110±5)VAC/(125±5)VAC when30%<load≤60%, 110VAC:(60±3) VAC /(75±3) VAC when load≤60% |
220VAC:(120±5) VAC /(135±5) VAC when60%<load≤70%, , 110VAC:(70±3) VAC /(75±3) VAC when60%<load≤70% |
220VAC:(140±5) VAC /(155±5) VAC when70%<load≤80% , 110VAC:(70±3) VAC /(85±3) VACwhen70%<load≤80% |
220VAC:(160±5) VAC /(170±5) VAC when load>80%, 110VAC:(80±3 VAC /(85±3) VAC when load>80% |
(300±5)VAC/(285±5)VAC when 0%≤load<100% |
Output |
Voltage range |
200VAC/208VAC/220VAC/230VAC/240VAC/110VAC/120VAC, need confirm before order |
Frequency range |
50Hz or 60HZ+-0.2Hz(Battery mode) |
Wave form |
Pure Sine Wave |
Transfer time |
0 ms, Between Line mode and Bat mode |
Transfer time: 4ms (typical 2.5ms), line Mode and bypass mode |
Distortion |
≤4%,Full R load |
≤4%,Full R load |
≤4%,Full R load |
Degree of distortion |
≤7%,Full RCD load |
≤7%,Full RCD load |
≤7%,Full RCD load |
Overload capacity |
100%±5%≤150%±5% 30s ;105%±5%≤125%±5% 60S; load>150%±5%, 300MS to bypass |
Load peak ratio |
3:1(max) |
Standard Modes XG1-3K |
Battery Type |
Maintenance free valve regulated lead acid (VRLA) battery |
Battery voltage |
24VDC or 36VDC |
48VDC or 72VDC |
72VDC or 96VDC |
Internal Battery |
2*7AH(9AH) or 3*7AH |
4*7AH(9AH) or 6*7AH(9AH) |
6*7AH(9AH) or 8*7AH |
Recharge time |
5 hours to 90%capacity |
Charge Current |
1A |
1A |
1A |
Long backup ModeXG1-3KS |
Battery bank |
36VDC, External |
72VDC,External |
96VDC,External |
Charge Current |
5Amp,Max 7Amp |
5Amp,Max 7Amp |
5Amp,Max 7Amp |
Display |
LED Display |
Line , Inverter , Bypass, battery |
LCD Mode |
input output HZ/VAC, Bat %/VDC, Load % and VA/Watts,Temp.LCD For input output HZ/VAC, Bat %/VDC, Load % and VA/Watts,Temp. LED for line,bat, Inverter, Bypss |
Audible Alarm |
Battery Mode |
Beeping every 4 seconds (re-settable) and every second when battery low |
Overload |
Beeping every 1 min |
Fault |
Beeping Continuously |
Bettery low/charger fault |
Beeping every 1 min |
Bypass mode |
Beeping every 2 min |
L/N inverse |
Beeping every 2 min |
Communications |
RS-232/USB Interface |
RS232 or USB, With monitoring software |
Working Environment |
Surge protection |
RJ-45 I/O port available for network or Fax/Modem |
Working temperature |
0℃~40℃ |
Humidity |
20%~95% non-condensing |
Product size |
WxDxH (mm) |
350*145*230(H) |
430*190*328(H) |
430*190*328(H) |
PCS/CTN |
|
2 |
1 |
1 |
CTN size |
WxDxH (mm) |
495*470*340(H) |
570*305*450 (H) |
570*305*450 (H) |
N/W, CTN XG1-3K |
Kg |
19/23 (base on 7AH) |
10/22.2 (base on 7AH) |
10/26.3 (base on 7AH) |
N/W, CTN XG1-3KS |
KG |
12 |
12 |
12 |
G/W, CTN XG1-3K |
Kg |
21/25 |
12/24.2 |
12/28.3 |
G/W, CTN XG1-3KS |
KG |
15 |
14 |
14 |
REMARK |
XG*K --- Standard Type Internal battery, XG*KS---- Long backup Type,External battery |
|
|
|
|