Product Name:High Frequency Online UPS RXG1-3KVA(T) Series
     
     Key Features

    ◆ LCD Rack Mounting High frequency  online UPS 1K 2K 3KVA

    ◆ DSP digital control,double conversion,Zero transfer time

    ◆ Single phase sine wave, output PF 0.8/0.9, 3-level inverter technology

    ◆ LCD display rotatable, setup output VAC and Hz by Monitor

    ◆ Self-testing, ECO function and adjustable VAC and HZ by panel

    ◆ Advanced Input PFC technology, 0.99

    ◆ Wide input voltage range, input Frequency 40-60HZ,support Generator

    ◆ Advanced battery management function,charging while UPS off mode

    ◆ Lightning and surge protection, Short circuit and overload protection

    ◆ RS232 or USB communication with monitoring software

    ◆ SNMP, EPO option, Rack mounting and Tower convertor Option

     


    RXG 1-3K (T)

     
      Technical Specifications

     

    Item

    Model

    RXG1K(T)

    RXG1KS(T)

    RXG2K(T)

    RXG2KS(T)

    RXG3K(T)

    RXG3KS(T)

    Capacity

    VA / Watts (220V)

    1KVA/ 0.9KW

    1KVA / 0.8KW

    2KVA/  1.8KW

    2KVA / 1.6KW

    3KVA/  2.7KW

    3KVA / 2.4KW

    VA / Watts (110V)

    1KVA/0.8KW

    1KVA / 0.8KW

    2KVA/1.6KW

    2KVA / 1.6KW

    3KVA/2.4KW

    3KVA / 2.4KW

    Input

    Normal voltage

    220VAC or 110VAC

    Turn on Voltage range

    90±5300±5)VAC or ( 60±5-138±5)VAC

    Frequency range

    4060Hz(adjustable)

    Input power factor

    >0.99(220VAC,full R load)

    Generator

    Support generator input(Generator rating2*UPS rating )

    line low loss/comeback

    220VAC:(110±5)VAC/(125±5)VAC when 30%<load60,   110VAC:(60±3) VAC /(75±3) VAC when load60

    220VAC:(120±5) VAC /(135±5) VAC when 60%<load70   110VAC:(70±3) VAC /(75±3) VAC when 60%<load70

    220VAC:(140±5) VAC /(155±5) VAC when 70%<load80,   110VAC:(70±3) VAC /(85±3) VAC when 70%<load80

    220VAC:(160±5) VAC /(170±5) VAC when load80,   110VAC:(80±3 VAC /(85±3) VAC when load80

    220VAC:(300±5)VAC/(285±5)VAC when 0load100,   110VAC:(138±3)VAC/(133±3)VAC when 0load100

    Output

    Voltage range

    200VAC/208VAC/220VAC/230VAC/240VAC/110VAC/120VAC ± 1% , Adjustable by Monitor

     Frequency range

    50Hz/60Hz+-0.2  (Battery mode)

    Wave form

    Pure Sine Wave

    Transfer time

    0 ms (AC  mode and battery mode)

    Transfer time: 4ms (typical 2.5ms),AC  mode and bypass mode

    Harmonic Distortion

    THD (Linear Load)≤2%THD (Non-linear Load)≤4%

     Overload capacity

    100%±5%150%±5% 30s ; 105%±5%125%±5% 60s,load>150%±5%, 300MS to bypass

    Load peak ratio

    31max

    Battery

    Installation

    Internal

    External

    Internal

    External

     Internal

    External

    Type

    Maintenance free valve regulated lead acid (VRLA) battery

    Battery voltage

    36VDC/24VDC

    36VDC

    72VDC/48VDC

    72VDC

    96VDC/72VDC

    96VDC

    Battery number  

    3*12V*7AH or 2*12V*7AH

    External

    6*12V*7AH or 4*12V*7AH

    External

    8*12V*7AH 3U or 6*12V*7AH 2U

    External

    Charge Current

    1Amp

    5Amp,Max 7Amp

    1Amp

    5Amp,Max 7Amp

    1Amp

    5Amp,Max 7Amp

    Recharge time

    90%capacity after 5 hrs charging

    depended on battery

    90%capacity after 5 hrs charging

    depended on battery

    90%capacity after 5 hrs charging

    depended on battery

    Bypass

    bypass

    Automatic while overload or ups fail.

    Before ON

    Default ON. Workable set by Winpower

    Voltage Range

    220VAC: 80VAC~286VAC (default: 80VAC~264VAC Could be adjusted by software)/ 110VAC:40VAC~133VAC

    Display

    LED

    Line , Inverter , Bypass, battery  

    LCD  Option

    input output HZ/VAC, Bat %/VDC, Load % and VA/Watts,Temp.LCD For input output HZ/VAC, Bat %/VDC, Load % and VA/Watts,Temp. LED for line,bat, Inverter, Bypss

    Audible Alarm

    Battery Mode

    Beeping every 4 seconds (re-settable) and every second when battery low

    Overload

    Beeping every 2 min

    Fault

    Beeping Continuously

    Bettery low/charger fault

    Beeping every 1 min

    Bypass mode

    Beeping every 2 min

    L/N inverse

    Beeping every 2 min

    Communications

    RS-232/USB Interface

    RS232 or USB to select , With monitoring software. Default USB

    Working  Environment

    Surge protection

    RJ-45  I/O port available for network or Fax/Modem

    Working temperature

    0℃~40

     Humidity

    0-95% non-condensing

    UPS Product size

    D*W*H(mm)

    450*482.6*88 2U

    450*482.6*88 2U

    665*482.6*88 2U

    450*482.6*88 2U

    665*482.6*132 3U

    450*482.6*88 2U

    UPS CTN size

    D*W*H(mm)

    570*550*225(H)

    570*550*225(H)

     785*560*197(H)

    570*550*225(H)

    785*575*265(H)

    570*550*225(H)

    UPS CTN weight

    Kg/PCS

    15.6 or 18Kg/PCS

    11Kg/PCS

    21.5 or 26Kg

    14Kg/PCS

    26.3 or 36Kg/PCS

    14Kg/1PCS

    Battery pack RBP 607

    size and weight

    Product size 450*482.6*88 2U, CTN 570*550*225mm(H), CTN G/W: 20Kg

    Battery pack RBP 807

    size and weight

    Product size 450*482.6*88 2U, CTN 570*550*225mm(H), CTN G/W: 24.5Kg

    OPTION

    Rack Mounting andTower  Converter,SNMP, EPO,

     REMARK

    RXG*K (T)--- Standard Type, RXG*KS (T)---- Long Time Type.  T:  Rack Mounting and Tower Converter



     
    The UPS operating principle

     





     
     

    Tel: 0086-574-88216630    Fax: 0086-574-8813 8440    Email: kema@kemapower.com
    Factory:H/Block Beiyue Industrial Zone,Foshan,China.
    Ningbo office:R505-1,TAIKANG MIDDLE ROAD 468#,YINZHOU DISTRICT, NINGBO,CHINA
    ?2004-2018 Kemapower Electronics Co., LTD.    All rights reserved