Product Name:Low Frequency Online UPS NTA2-20K
     

     Key Features
     
    ◆ Low Frequency Single phase Online UPS 3-20KVA

    ◆ Microprocessor control, IGBT technology, True on-line double conversion design

    ◆ Sine wave Isolated output, Zero transfer time

    ◆ Generator compatible

    ◆ Full protection for Overload,short circuit,Battery low and else

    ◆ LED and LCD display , LCD Monitor with event log

    ◆ Advanced Battery Management

    ◆ Smart RS-232  communication port

    ◆ SNMP card, ECO, EPO Function option
     

     
     Technical Specifications
     

    Model

    NTA 2K(B)

    NTA 3K(B)

    NTA 6K

    NTA 10K

    NTA 15K

    NTA 20K

    Input

    Rated voltage

    220VAC  or 110V

    Phase

    L+N+G

    Voltage Range

    220 or 110±25% VAC

    Rated frequency

    50Hz or 60HZ

    Frequency Range

    40-60HZ, default:46~54Hz, adjustable by softwave

    power factor

    Max 0.8

    Generator

    Support generator input, 2*UPS rating

    Output

    VA/watt

    2KVA/1.6kW

    3KVA/2.4KW

    6KVA/4.8KW

    10KVA/8KW

    15KVA/12KW

    20KVA/16KW

    Rated voltage

    220 or 110VAC ±2%

    Phase

    L+N+G

    Voltage range

    200/208/220/230/240VAC, Could be adjusted by software. 10% derating for 208VAC/200VAC

    Bypass output before turn-on

    Yes

    Crest ration

    3:01

    Frequency 

    50Hz

    Efficiency Line mode

    > 80% (R Load)

    > 87% (R Load)

    Efficiency Battery mode

    > 85% (R Load)

    > 88% (R Load)

    Overload

    line mode/battery mode 

    Overload warning only

    2Minthen transfer to bypass and alarm.

    30Sthen transfer to bypass and alarm.

    0.5Sthen transfer to bypass and alarm.

    Automatically recovery

    Yes

    Short circuit protection

    Line/battery mode

    Cut off output and alarm after 3S

    Transfer time

    Line to battery mode

    0mS, Line/battery mode

    Battery

    Rated voltage

    192VDC

    Standard mode

    16*7AH

    16*7AH

    N/A

    .N/A

    .N/A

    .N/A

    Protection

    Low alarm voltage/
    comeback voltage

    (180.8V±4V)/ (188.8V±4V)

    Shutdown voltage

    (176V±4V)/ (184V±4V)

    (160V±4V)/ (168V±4V)

    Battery protection

    Overcharge protection

    (250V±4V)

    Battery self test

    Support, Weak and Fault

    Charger

    Output voltage

    (220±2)VDC, Floating Charge

    Charge time

    Determined by battery capacity

    Charging  current

    1.5A/5A

    1.5A/5A

    7A

    7A

    7A

    7A

    Interface

    Alarm silence

    Support

    DC power turn-on

    Support

    Automatically restart

    Support

    Alarm

    Battery mode

    Beep/4s

    Battery low/charger fault

    Beep/1s

    UPS fault

    Continuously beep

    Overload

    Beep/1s

    Bypass mode

    Beep/2Min

    Communication

    RS232/RS485 with Monitor softwave ,Intelligent slot, SNMP Optoion

    Cooling

    Force air cooling

    Yes

    Display

    LED and LCD

    input output HZ/VAC, Bat %/VDC, Load % and VA/Watts,Temp.LCD For input output HZ/VAC, Bat %/VDC, Load % and VA/Watts,Temp. LED for line,bat, Inverter, Bypss

    Environment

    Work temperature

    040

    Altitude

    1000m

    Audible noise

    ≤55dB

    Storage temperature

    1545

    Work humidity

    20%95

    Product size

    L*W*H(mm)

    560*260*717mm

    900*370*655

    Package size

    L*W*H(mm)

     710*990*440mm

    1054*450*730

    N.W.

    N.W.(Kg)

    85(16*9AH)/37

    89(16*7AH)/40

    58

    62

    155

    160

    G.W.

    weight(Kg)

    101(16*7AH)/42

    105(16*7AH)/45

    56

    80

    170

    175


         

     Back view 6K8K10K

     Back view 15K20K

     LED LCD Display







     
     

    Tel: 0086-574-88216630    Fax: 0086-574-8813 8440    Email: kema@kemapower.com
    Factory:H/Block Beiyue Industrial Zone,Foshan,China.
    Ningbo office:R505-1,TAIKANG MIDDLE ROAD 468#,YINZHOU DISTRICT, NINGBO,CHINA
    ?2004-2018 Kemapower Electronics Co., LTD.    All rights reserved