Product Name£ºHigh Frequency Online UPS XG10K
     
    Key Features

    ¡ô LCD High frequency double conversion sine wave online UPS
    ¡ô DSP digital control technology, Zero transfer time
    ¡ô Single Phase Sine Wave, Output Power Factor 0.9-1 adjustable VAC and Hz by panel
    ¡ô Wide Input Voltage and Frequency Range, Support Generator
    ¡ô Advanced Input PFC Technology 0.99
    ¡ô Self-testing and battery management function
    ¡ô Automatic battery charging while UPS off mode
    ¡ô Lightning, Surge, Short Circuit and Overload Protection, Alarm or Silence Settable
    ¡ô USB communication with monitoring software

     
    Technical Specifications

    Item

    Model

    XG10K

    Capacity

    VA / Watts

    10KVA / 9KW

    Input

    AC Input voltage

    220 to 240VAC

    AC Operating voltage range

    208 to 240VAC

    Frequency range

    60Hz ± 5%

    Input power factor

    >0.99(220VAC,full R load)

    Generator

    Support generator input(Generator rating¡Ý2*UPS rating )

    Output

    AC Output voltage

    220 to 240VAC

    Frequency range

    60Hz ± 5%

    Wave form

    Pure Sine Wave

    Transfer time

    0 ms, Between Line mode and Bat mode

    Transfer time: 4ms (typical 2.5ms), line Mode and bypass mode

    Voltage distortion

    ¡Ü6%,Full RCD load

    Voltage distortion

    ¡Ü2%,Full R load

    Overload capacity

    ¡Ü105%+-5% warning only, 105%+-5%<Load¡Ü125% +-5%1ms to bypass; 125%±5%<load¡Ü135%±5% 30S to bypass,
    Load>135%±5% 100MS to bypass

    Load peak ratio

    3£º1(max)

    Receptacles

    6*NEMA 5-15R, ¡Ý6(min.)

    Battery

    Battery Type

    Maintenance free valve regulated lead acid (VRLA) battery

    Battery Runtime

    ¡Ý15 minutes at full load

    Recharge time

    3.5 hours to 90% capacity

    Charge Current

    2.5A

    Display

    LED Display

    Line, Inverter, Bypass, Battery

    LCD Panel

    LCD for power status, input output HZ/VAC, battery %/VDC, load % and VA/Watts, temp. fault code

    Audible Alarm

    Battery Mode

    Beeping every 4 seconds (re-settable) and every second when battery low

    Overload

    Beeping twice every second

    Fault

    Beeping Continuously

    Battery low/charger fault

    Beeping every 1 second

    Bypass mode

    Beeping every 2 min

    L/N inverse

    Beeping every 2 min

    Protection

    Surge energy rating

    ¡Ý480 joules

    Communications

    USB Interface

    USB, with monitoring software

    Working
    Environment

    Surge protection

    RJ-45 I/O port available for network or Fax/Modem

    Working Temperature

    - 20¡æ¡«40¡æ

    Humidity

    0-95% non-condensing

    Product size

    WxDxH(mm)

    260*533*560

    Product Weight

    Kg

    70


     
     