Product Name£ºHIGH FREQUENCY RACK/TOWER MOUNTING ONLINE UPS
     
    Features

    ¡ô LCD Rack / Tower Mounting High Frequency Online UPS
    ¡ô DSP digital control, Double Conversion, Zero Transfer Time
    ¡ô Single Phase Sine Wave, Output Power Factor 1
    ¡ô LCD Display Rotatable, to meet mounting and tower convertor requirement
    ¡ô Self-testing, ECO function and adjustable VAC and Hz by panel
    ¡ô Wide Input Voltage Range, Input Frequency 47-70Hz, Support Generator
    ¡ô Advanced Battery Management Function, Charging while UPS off mode
    ¡ô Lightning and Surge Protection, Short Circuit and Overload Protection
    ¡ô USB communication with monitoring software
    ¡ô SNMP, Rail Kit, Rack Mounting and Tower Convertor option

     
    Technical Specification

    Item

    Model

    RXG1.5K

    Capacity

    VA / Watts (220V)

    1500VA / 1500W

    Input

    Normal voltage

    220VAC

    Voltage range

    Without using batteries: 160V-294V (adjustable to 150V-294V)

    Frequency range

    Without using batteries: 47 to70Hz

    Input power factor

    >0.99(220VAC,full R load)

    Generator

    Support generator input(Generator rating¡Ý2*UPS rating)

    Output

    Voltage range

    Atleast 230V (+6/-10%) (Adjustable to 200VAC/208VAC/220VAC/230VAC/240VAC) 50/60Hz +/-0.1Hz (auto sensing)

    Frequency range

    50Hz/60Hz+-0.1 (Battery mode) Auto-sensing

    Waveform

    Pure Sine Wave, Booster and Fader

    Transfer time

    0 ms (AC mode and battery mode)

    Transfer time: 4ms (typical 2.5ms),AC mode and bypass mode

    Distortion

    ¡Ü4% ,Full load, Full Load, linear load

    Degree of distortion

    ¡Ü7%, (Full Load, nonlinear load)

    Overload capacity

    <105% warning only, <125% 30s ; <150% 20s,>150%, 300MS to bypass

    Load peak ratio

    3 £º1£¨max£©

    Battery Pack

    Type

    Maintenance free valve regulated lead acid (VRLA) battery

    Charge Current

    1Amp

    Recharge time

    90%capacity after 5 hrs charging

    Bypass

    Bypass

    Automatic while overload or ups fail.

    Before ON

    Default ON. Workable set by Winpower

    Voltage Range

    (80±5)VAC~ (286±5)VAC (default: 80VAC~264VAC Could be adjusted by software)

    Display

    LED

    Line , Inverter , Bypass, battery

    LCD Option

    Input Output HZ/VAC, Bat %/VDC, Load % and VA/Watts,Temp.LCD For input output HZ/VAC, Bat %/VDC, Load % and VA/Watts,Temp. LED for line,bat, Inverter, Bypass

    Audible Alarm

    Battery Mode

    Beeping every 4 seconds (re-settable) and every second when battery low

    Overload

    Beeping twice every second

    Fault

    Beeping Continuously

    Battery low/charger fault

    Beeping every 1 second

    Bypass mode

    Beeping every 2 min

    L/N inverse

    Beeping every 2 min

    Communications

    RS-232/USB Interface

    RS232 or USB to select, With monitoring software. Default USB

    Working Environment

    Surge protection

    RJ-45 I/O port available for network or Fax/Modem

    Working temperature

    - 20¡æ~40¡æ

    Humidity

    0-95% non-condensing

    UPS Product size

    WxDxH (mm)

    483 x 450 x 88 (2U)

     
     