Product Name£º | High Frequency ONLINE UPS |
Features |
¡ô LCD High frequency double conversion sine wave online UPS1K 2K 3KVA
¡ô DSP digital control technology, Zero transfer time
¡ô Single phase,output PF 0.8/0.9, adjustable VAC and HZ by panel
¡ô Wide input voltage range 115-300V(220V) or 60-138V(110V)
¡ô Wide input Frequency 40-60HZ,support Generator
¡ô Advanced Input PFC Technology 0.99
¡ô Self-testing, ECO and Advanced battery management function
¡ô Automatic battery charging while UPS off mode
¡ô Lightning and Surge Protection, Short Circuit and Overload Protection
¡ô RS232 or USB communication with monitoring software
¡ô SNMP, EPO option
|
 |
|
Item |
Model |
XG1K/1KS |
XG2K/2KS |
XG3K/3KS |
Capacity |
VA / Watts |
1KVA / 0.8KW or 0.9KW |
2KVA / 1.6KW or 1.8KW |
3KVA / 2.4KW or 2.7KW |
Input |
Normal voltage |
220VAC or 110VAC |
Turn on Voltage range |
£¨90±5¡«300±5£©VAC or ( 60~ 138)VAC |
Frequency range |
40¡«60Hz(adjustable) |
40¡«60Hz(adjustable) |
40¡«60Hz(adjustable) |
Input power factor |
0.99(220VAC,full R load) |
Generator |
Support generator input(Generator rating¡Ý2*UPS rating ) |
line low loss/comeback |
220VAC:(110±5)VAC/(125±5)VAC when30£¥£¼ load¡Ü60£¥, 110VAC:(60±3) VAC /(75±3) VAC when load¡Ü60% |
220VAC:(120±5) VAC /(135±5) VAC when60£¥£¼ load¡Ü70£¥, , 110VAC:(70±3) VAC /(75±3) VAC when60£¥£¼ load¡Ü70% |
220VAC:(140±5) VAC /(155±5) VAC when70£¥£¼ load¡Ü80£¥ , 110VAC:(70±3) VAC /(85±3) VACwhen70£¥£¼ load¡Ü80% |
220VAC:(160±5) VAC /(170±5) VAC when load£¾80£¥, 110VAC:(80±3 VAC /(85±3) VAC when load£¾80% |
(300±5)VAC/(285±5)VAC when 0%¡Ü load£¼100% |
Output |
Voltage range |
200VAC/208VAC/220VAC/230VAC/240VAC/110VAC/120VAC, need confirm before order |
Frequency range |
50Hz or 60HZ+-0.2Hz(Battery mode) |
Wave form |
Pure Sine Wave |
Transfer time |
0 ms, Between Line mode and Bat mode |
Transfer time: 4ms (typical 2.5ms), line Mode and bypass mode |
Distortion |
¡Ü3%,Full R load |
¡Ü3%,Full R load |
¡Ü3%,Full R load |
Degree of distortion |
¡Ü7%,Full RCD load |
¡Ü7%,Full RCD load |
¡Ü7%,Full RCD load |
Overload capacity |
100%±5%<load warning only, 125%±5%<load¡Ü150%±5% 30s ;105%±5%<load¡Ü125%±5% 60S; load>150%±5%, 300MS to bypass |
Load peak ratio |
3£º 1£¨max£© |
Efficiency |
Up to 98% |
Standard Modes XG1-3K |
Battery Type |
Maintenance free valve regulated lead acid (VRLA) battery |
Battery voltage |
24VDC or 36VDC |
48VDC or 72VDC |
72VDC or 96VDC |
Internal Battery |
2*7AH(9AH) or 3*7AH |
4*7AH(9AH) or 6*7AH(9AH) |
6*7AH(9AH) or 8*7AH |
Recharge time |
5 hours to 90%capacity |
Charge Current |
1A |
1A |
1A |
Long backup ModeXG1- 3KS |
Battery bank |
36VDC, External |
72VDC,External |
96VDC,External |
Charge Current |
5Amp,Max 7Amp |
5Amp,Max 7Amp |
5Amp,Max 7Amp |
Display |
LED Display |
Line , Inverter , Bypass, battery |
LCD Mode |
input output HZ/VAC, Bat %/VDC, Load % and VA/Watts,Temp.LCD For input output HZ/VAC, Bat %/VDC, Load % and VA/Watts,Temp. LED for line,bat, Inverter, Bypss |
Audible Alarm |
Battery Mode |
Beeping every 4 seconds (re-settable) and every second when battery low |
Overload |
Beeping every 1 min |
Fault |
Beeping Continuously |
Bettery low/charger fault |
Beeping every 1 min |
Bypass mode |
Beeping every 2 min |
L/N inverse |
Beeping every 2 min |
Communications |
RS-232/USB Interface |
RS232 or USB, With monitoring software |
Working Environment |
Surge protection |
RJ-45 I/O port available for network or Fax/Modem |
Working temperature |
0¡æ~40¡æ |
Humidity |
20%¡«95£¥ non-condensing |
Noise level at 1m |
<40dBA |
Product size |
WxDxH (mm) |
350* 145*230(H) |
430* 190*328(H) |
430* 190*328(H) |
PCS/CTN |
|
2 |
1 |
1 |
CTN size |
WxDxH (mm) |
495*470*340(H) |
570*305*450 (H) |
570*305*450 (H) |
N/W, CTN XG1-3K |
Kg |
19/23 (base on 7AH) |
10/22.2 (base on 7AH) |
10/26.3 (base on 7AH) |
N/W, CTN XG1-3KS |
KG |
12 |
12 |
12 |
G/W, CTN XG1-3K |
Kg |
21/25 |
12/24.2 |
12/28.3 |
G/W, CTN XG1-3KS |
KG |
15 |
14 |
14 |
REMARK |
XG*K --- Standard Type Internal battery, XG*KS---- Long backup Type,External battery |
 |
|
|