Product Name£ºHigh Frequency ONLINE UPS
     
    Features

    ¡ô LCD High frequency double conversion sine wave online UPS
    ¡ô DSP digital control technology, Zero transfer time
    ¡ô Single Phase Sine Wave, Output Power Factor 0.9
    ¡ô Wide Input Voltage Range, Wide Input Frequency
    ¡ô Support Generator, Output Hz be fixed or follow mains
    ¡ô Advanced Input PFC Technology 0.99
    ¡ô Self-testing, ECO and Advanced battery management function
    ¡ô Automatic battery charging while UPS off mode
    ¡ô Lightning and Surge Protection, Short Circuit and Overload Protection
    ¡ô USB communication with monitoring software
    ¡ô Form Factor: Tower

     
    Technical Specification

    Item

    Model

    XG3K

    Capacity

    VA / Watts

    3KVA / 2.7KW

    Input

    Voltage

    220/230/240VAC

    Frequency range

    60Hz ± 2Hz

    Input power factor

    >0.99(220VAC,full R load)

    Generator

    Support generator input(Generator rating¡Ý2*UPS rating )

    Output

    Voltage range

    220~240VAC±1%

    Frequency range

    50Hz or 60HZ+-0.2Hz(Battery mode)

    Wave form

    Pure Sine Wave

    Transfer time

    0 ms, Between Line mode and Bat mode
    Transfer time: 4ms (typical 2.5ms), line Mode and bypass mode

    Distortion

    ¡Ü4%,Full linear load

    Degree of distortion

    ¡Ü7%,Full nonlinear load

    Overload capacity

    <105% warning only, <125% 30s ; <150% 20s,>150%, 300MS to bypass

    Load peak ratio

    3£º1£¨max£©

    Receptacles

    4*NEMA 5-15R

    Battery

    Battery Type

    Maintenance free valve regulated lead acid (VRLA) battery

    Battery voltage

    72VDC

    Recharge time

    5 hours to 90%capacity

    Charge Current

    1A

    Display

    LED Display

    Line , Inverter , Bypass, battery

    LCD Mode

    input output HZ/VAC, Bat %/VDC, Load % and VA/Watts, Temp. LCD For input output HZ/VAC, Bat %/VDC, Load % and VA/Watts,Temp. LED for line,bat, Inverter, Bypass

    Audible Alarm

    Battery Mode

    Beeping every 4 seconds (re-settable) and every second when battery low

    Overload

    Beeping twice every second

    Fault

    Beeping Continuously

    Battery low/charger fault

    Beeping every 1 second

    Bypass mode

    Beeping every 2 min

    L/N inverse

    Beeping every 2 min

    Communications

    RS-232/USB Interface

    USB with monitoring software

    Working
    Environment

    Surge protection

    RJ-45 I/O port available for network or Fax/Modem

    Working temperature

    - 20¡æ¡«40¡æ

    Humidity

    0-95% non-condensing

    Product Size

    WxDxH (mm)

    430*190*328

    Product Weight

    Kg

    23

                        
     
     

    Tel: 0086-574-88216630    Fax: 0086-574-8813 8440    Email: kema@kemapower.com
    Factory:H/Block Beiyue Industrial Zone,Foshan,China.
    Ningbo office:R505-1,TAIKANG MIDDLE ROAD 468#,YINZHOU DISTRICT, NINGBO,CHINA