Product Name£ºHigh Frequency ONLINE UPS
     
    Features

    ¡ô LCD High frequency double conversion sine wave online UPS
    ¡ô DSP digital control technology, Zero transfer time
    ¡ô Single Phase Sine Wave
    ¡ô Wide Input Voltage Range
    ¡ô Wide Input Frequency, Support Generator
    ¡ô Self-testing, ECO and Advanced battery management function
    ¡ô Automatic battery charging while UPS off mode
    ¡ô Lightning and Surge Protection, Short Circuit and Overload Protection
    ¡ô USB communication
    ¡ô Signal indication during battery mode, low battery and other fault detected on the UPS

     
    Technical Specification

    Item

    Model

    XG2K-407

    Capacity

    VA/ Watts

    2KVA/2KW

    Input

    Nominal voltage

    220/230/240VAC

    Voltage range

    160-270VAC

    Frequency

    50/60Hz

    Frequency range

    45-65Hz

    Input power factor

    1.0

    Generator

    Support generator input (Generator rating¡Ý2*UPS rating)

    Input power cord

    Detachable 1*line to line, 1*Neutral ground, 1*Earth ground (green)

    Output

    Nominal voltage

    220/230/240VAC

    Voltage regulation

    +/-1%

    Frequency range

    50Hz or 60HZ+-0.2Hz (Battery mode)

    Output power factor

    1.0

    Wave form

    Pure Sine Wave

    Transfer time

    0 ms

    Crest factor

    3:1 of total harmonic distortion (THD) at linear load

    Harmonic distortion

    <3% of total harmonic distortion (THD) at linear load

    Overload capacity

    <105% warning only, <125% 30s; <150% 20s,>150%, 300MS to bypass

    Overload capability

    Able to sustain for at least 60sec. in case of 100% load without abnormal behavior of UPS

    Efficiency

    Minimum of 88% during AC mode
    Minimum of 83% during battery mode

    Output outlet

    Standard design 3 prong parallel outlet 1*line to line, 1*Neutral ground, 1*Earth ground (green)

    Battery

    Battery type

    Sealed maintenance free valve regulated lead acid (VRLA) battery

    Battery runtime

    15mins (minimum) at ATM full load

    Recharge time

    5 hours to 90%capacity

    Charge current

    1A

    Display

    LED display

    Line, Inverter, Bypass, battery

    LCD display monitor

    LCD for Input Output Voltage Frequency, Bat %/VDC, Load in Watts, Temperature, Load Percentage,
    LED for line, bat, Inverter, Bypass

    Audible Alarm

    Battery mode

    Beeping every 4 seconds (re-settable) and every second when battery low

    Overload

    Beeping twice every second

    Fault

    Beeping Continuously

    Battery low/charger fault

    Beeping every 1 second

    Bypass mode

    Beeping every 2 min

    L/N inverse

    Beeping every 2 min

    Communications

    RS-232/USB Interface

    RS232 or USB, With monitoring software

    Working Environment

    Surge protection

    RJ-45 I/O port available for network or Fax/Modem

    Operating temperature

    0¡æ-40¡æ

    Humidity

    0-95% non-condensing

    Protection

    Overload, Low input voltage, Surge input voltage per UL 1449, Overheat in the UPS

    Product Size

    WxDxH (mm)

    430*190*328(H)

    Product Weight

    Kg

    19

     
     

    Tel: 0086-574-88216630    Fax: 0086-574-8813 8440    Email: kema@kemapower.com
    Factory:H/Block Beiyue Industrial Zone,Foshan,China.
    Ningbo office:R505-1,TAIKANG MIDDLE ROAD 468#,YINZHOU DISTRICT, NINGBO,CHINA