Product Name£ºOff Grid Hybrid Solar inverter SUB-D 3-11KW
     
      Features

    ¡ô High Frequency off grid hybrid solar inverter SUB-D 3-11KW ,PF=1
    ¡ô 3 in 1 design, Power Inverter + MPPT controller + Grid Charger
    ¡ô Working without battery during daytime
    ¡ô Support lithium activation wake-up and cold start function
    ¡ô Auto restart while AC is recovering
    ¡ô Intelligent power supply mode, intelligent Distribution of solal panel/mains/battory power shares
    ¡ô AC and PV charge voltage adjustable, meet different types battery charge requirements
    ¡ô Adjustable Charge Current & Voltage, selectable Lead acid / Lithium battery
    ¡ô Solar,Grid and Battery Energy complement each other,priority selectable
    ¡ô RS232, BMS/RS485,Dry Contact Communication
    ¡ô WiFi Plug or GPRS option for Mobile App, Automatic generator startion option
    ¡ô Economical model optional for 3KW , small capacity MPPT and PV input
    ¡ô 6.2KW/11KW grid tie and parallel funciton option , max 9 units
    ¡ô Wide MPPT range 40--500VDC/120-500VDC, 60A/100A/150A for different modes
    ¡ô Intelligent 3 stage AC battery charger, 60/80A/150A for different modes
    ¡ô Selectable Utility,Solar or Battery priority, power Saver Modes
    ¡ô Pure sine wave output, suitable for different loads
    ¡ô Protection for overload, over temperature,short-circuit, battery Low, battery reverse connection

     

     

     
      Technical Specifications
    ITEM Model SUB-D-E3024 SUB-D-3624 SUB-D-6248 SUB-D-11048 SUB-D-6248GP SUB-D-11048GP
    INPUT RATED POWER 3KW 3.6KW 6.2KW 11KW 6.2KW 11KW
    Voltage 220/230/240VAC
    Selectable Voltage Range 170-280VAC¡À3V (For Personal Computers)
    90-280VAC ¡À3V(For Home Appliances)
    Frequency Range 50 Hz/60 Hz (Auto sensing)
    OUTPUT Voltage 220/230/240VAC ¡À 5%(Bat Mode)
    Surge Power 2 times Rated power for 5 seconds
    Overload Protection 21s@105%~150% Load; 11s@150%~200% Load; 400ms@>200% Load
    Efficiency,PV to INV. 97% (Peak)
    Efficiency,Battery to INV. 94%(Peak)
    Transfer Time 10 ms (For Personal Computers) ; 20 ms (For Home Appliances)
    Waveform Pure sine wave
    Parallel Extension infeasible infeasible infeasible infeasible Max 9PCS Max 9PCS
    Output Grid Tie Connection Output Voltage NO 220/230/240VAC
    Grid Voltage Range NO 195-253VAC
    Grid Frequency Range NO 49-51¡À1Hz or 59-61¡À1Hz
    Output Current NO 26.9A 47.8A
    Power Factor Range NO >0.99
    Conversion Efficiency NO 98%
    BATTERY & AC CHARGER Battery Voltage 24 VDC 48 VDC
    Constant Charging Voltage(Adjustable) 28.2VDC 56.4VDC
    Floating Charge Voltage(Adjustable) 27 VDC 54 VDC
    Overcharge Protection 33 VDC 63 VDC
    Charge Current (Max) 60A 80A 80A 150A 80A 150A
    SOLAR CHARGER PV Array Power (Max) 3KW 4.2KW 6.2KW 2*5.5KW 6.2KW 2*5.5KW
    MPPT Range 50 ~ 500 VDC 150 ~ 500 VDC
    PV Work Range 300~400VDC
    PV Array Voltage (Max) 500 VDC
    Max PV Input Current 18A 18A 18A 18A/18A 18A 18A/18A
    Max PV Charge Current 60A 100A 100A 150A 100A 150A
    Max Charge Current 100A, AC+Solar adjustable 120A, AC+Solar adjustable 150A, AC+Solar adjustable 120A, AC+Solar adjustable 150A, AC+Solar adjustable
    Display LCD Input/Output V/HZ; Load %, VA/W; Overload; Bat % VDC; Bat Type; PV1/PV2 V/WH; Charge/Discharge Current; Setup; Fault Code and Warning; Working Mode
    LED AC/INV: Green Light Solid on¡ªOutput is powered by mains; Flashing¡ªOutput is powered by solar
    CHARGE: Green Light Solid on¡ªBattery is fully charged; Flashing¡ªBattery is charging
    FAULT: Red Light Solid on¡ª Inverter fault; Flashing¡ª Inverter warming
    Setup/Adjust Parameter Solar power /utility power/Battery priority, united Charge Current , AC Charge Amp, AC input range, VAC HZ, Bat VDC back to utility power, BAT VDC back to Bat Mode, Charge Source select ,Alarm on off , overload bypass, Bulk/ Floating Charge VDC, Bat Low Cut VDC , equalization Charge VDC / mins / days,
    Output Working Mode Utility Uower Priority default. Utility power priority, Solar and battery as backup when utility power not available
    Solar Priority(SUB Mode) solar power priority, utility power supplement to load when solar power is not enough , utility not available, battery supplement to load. Working on daytime while No Bat
    SBU Priority Solar power priority, When Solar power is not enough,battery to supplement.when battery power is not enough , utility power to load. Working on daytime while No Bat
    OPERATING ENVIRONMENT Humidity 20% to 95% Relative Humidity(Non-condensing)
    Altitude No more than 1000m, lf 1000m<,Rate power will lower, MAX 4000m, Refer to lEC62040
    Noise ¡Ü50db
    Operating Temperature -10¡ãC - 50¡ãC
    Storage Temperature ¨C15¡ãC - 60¡ãC
    Communication interface N/A RS232; BMS/RS485; WIFI Plug; Dry Contact; Parallel port for 6.2KW/11KW
    Product Size L*W*H 495*312*146 570*500*148 495*312*146 570*500*148
    Net Weight (kgs) Kg 9.13 10.52 10.79 18.99 10.79 18.99
    Carton Size L*W*H 565*385*195 708*570*241 565*385*195 708*570*241
    Carton Weight Kg 10.35 11.84 12.42 22.21 12.42 22.21
    REMARK SUB-GP Grid Tie + Parallel
     
     

    Tel: 0086-574-88216630    Fax: 0086-574-8813 8440    Email: kema@kemapower.com
    Factory:H/Block Beiyue Industrial Zone,Foshan,China.
    Ningbo office:R505-1,TAIKANG MIDDLE ROAD 468#,YINZHOU DISTRICT, NINGBO,CHINA
    ?2004-2018 Kemapower Electronics Co., LTD.    All rights reserved