Product Name£º | Off Grid Hybrid Solar inverter SUB-D 3-11KW |
Features |
¡ô High Frequency off grid hybrid solar inverter SUB-D 3-11KW ,PF=1
¡ô 3 in 1 design, Power Inverter + MPPT controller + Grid Charger
¡ô Working without battery during daytime
¡ô Support lithium activation wake-up and cold start function
¡ô Auto restart while AC is recovering
¡ô Intelligent power supply mode, intelligent Distribution of solal panel/mains/battory power shares
¡ô AC and PV charge voltage adjustable, meet different types battery charge requirements
¡ô Adjustable Charge Current & Voltage, selectable Lead acid / Lithium battery
¡ô Solar,Grid and Battery Energy complement each other,priority selectable
¡ô RS232, BMS/RS485,Dry Contact Communication
¡ô WiFi Plug or GPRS option for Mobile App, Automatic generator startion option
¡ô Economical model optional for 3KW , small capacity MPPT and PV input
¡ô 6.2KW/11KW grid tie and parallel funciton option , max 9 units
¡ô Wide MPPT range 40--500VDC/120-500VDC, 60A/100A/150A for different modes
¡ô Intelligent 3 stage AC battery charger, 60/80A/150A for different modes
¡ô Selectable Utility,Solar or Battery priority, power Saver Modes
¡ô Pure sine wave output, suitable for different loads
¡ô Protection for overload, over temperature,short-circuit, battery Low, battery reverse connection
|
|
|
ITEM |
Model |
SUB-D-E3024 |
SUB-D-3624 |
SUB-D-6248 |
SUB-D-11048 |
SUB-D-6248GP |
SUB-D-11048GP |
INPUT |
RATED POWER |
3KW |
3.6KW |
6.2KW |
11KW |
6.2KW |
11KW |
Voltage |
220/230/240VAC |
Selectable Voltage Range |
170-280VAC¡À3V (For Personal Computers) |
90-280VAC ¡À3V(For Home Appliances) |
Frequency Range |
50 Hz/60 Hz (Auto sensing) |
OUTPUT |
Voltage |
220/230/240VAC ¡À 5%(Bat Mode) |
Surge Power |
2 times Rated power for 5 seconds |
Overload Protection |
21s@105%~150% Load; 11s@150%~200% Load; 400ms@>200% Load |
Efficiency,PV to INV. |
97% (Peak) |
Efficiency,Battery to INV. |
94%(Peak) |
Transfer Time |
10 ms (For Personal Computers) ; 20 ms (For Home Appliances) |
Waveform |
Pure sine wave |
Parallel Extension |
infeasible |
infeasible |
infeasible |
infeasible |
Max 9PCS |
Max 9PCS |
Output Grid Tie Connection |
Output Voltage |
NO |
220/230/240VAC |
Grid Voltage Range |
NO |
195-253VAC |
Grid Frequency Range |
NO |
49-51¡À1Hz or 59-61¡À1Hz |
Output Current |
NO |
26.9A |
47.8A |
Power Factor Range |
NO |
>0.99 |
Conversion Efficiency |
NO |
98% |
BATTERY & AC CHARGER |
Battery Voltage |
24 VDC |
48 VDC |
Constant Charging Voltage(Adjustable) |
28.2VDC |
56.4VDC |
Floating Charge Voltage(Adjustable) |
27 VDC |
54 VDC |
Overcharge Protection |
33 VDC |
63 VDC |
Charge Current (Max) |
60A |
80A |
80A |
150A |
80A |
150A |
SOLAR CHARGER |
PV Array Power (Max) |
3KW |
4.2KW |
6.2KW |
2*5.5KW |
6.2KW |
2*5.5KW |
MPPT Range |
50 ~ 500 VDC |
150 ~ 500 VDC |
PV Work Range |
300~400VDC |
PV Array Voltage (Max) |
500 VDC |
Max PV Input Current |
18A |
18A |
18A |
18A/18A |
18A |
18A/18A |
Max PV Charge Current |
60A |
100A |
100A |
150A |
100A |
150A |
Max Charge Current |
100A, AC+Solar adjustable |
120A, AC+Solar adjustable |
150A, AC+Solar adjustable |
120A, AC+Solar adjustable |
150A, AC+Solar adjustable |
Display |
LCD |
Input/Output V/HZ; Load %, VA/W; Overload; Bat % VDC; Bat Type; PV1/PV2 V/WH; Charge/Discharge Current; Setup; Fault Code and Warning; Working Mode |
LED |
AC/INV: Green Light Solid on¡ªOutput is powered by mains; Flashing¡ªOutput is powered by solar
CHARGE: Green Light Solid on¡ªBattery is fully charged; Flashing¡ªBattery is charging
FAULT: Red Light Solid on¡ª Inverter fault; Flashing¡ª Inverter warming |
Setup/Adjust Parameter |
Solar power /utility power/Battery priority, united Charge Current , AC Charge Amp, AC input range, VAC HZ, Bat VDC back to utility power, BAT VDC back to Bat Mode, Charge Source select ,Alarm on off , overload bypass, Bulk/ Floating Charge VDC, Bat Low Cut VDC , equalization Charge VDC / mins / days, |
Output Working Mode |
Utility Uower Priority |
default. Utility power priority, Solar and battery as backup when utility power not available |
Solar Priority(SUB Mode) |
solar power priority, utility power supplement to load when solar power is not enough , utility not available, battery supplement to load. Working on daytime while No Bat |
SBU Priority |
Solar power priority, When Solar power is not enough,battery to supplement.when battery power is not enough , utility power to load. Working on daytime while No Bat |
OPERATING ENVIRONMENT |
Humidity |
20% to 95% Relative Humidity(Non-condensing) |
Altitude |
No more than 1000m, lf 1000m<,Rate power will lower, MAX 4000m, Refer to lEC62040 |
Noise |
¡Ü50db |
Operating Temperature |
-10¡ãC - 50¡ãC |
Storage Temperature |
¨C15¡ãC - 60¡ãC |
Communication interface |
N/A |
RS232; BMS/RS485; WIFI Plug; Dry Contact; Parallel port for 6.2KW/11KW |
Product Size |
L*W*H |
495*312*146 |
570*500*148 |
495*312*146 |
570*500*148 |
Net Weight (kgs) |
Kg |
9.13 |
10.52 |
10.79 |
18.99 |
10.79 |
18.99 |
Carton Size |
L*W*H |
565*385*195 |
708*570*241 |
565*385*195 |
708*570*241 |
Carton Weight |
Kg |
10.35 |
11.84 |
12.42 |
22.21 |
12.42 |
22.21 |
REMARK |
SUB-GP Grid Tie + Parallel |
|
| |