|
|
High Frequency Three Phase Online UPS 33XG10-40KVA ◆ LCD High Frequency Double Conversion Sine Wave Online UPS 10-40KVA ◆ Three phase sine wave, output power factor 0.9 ◆ Wide input voltage range 274-478V ◆ Wide input frequency 40-60Hz(50Hz)/50-70Hz(60Hz) ,support generator,output HZ be fixed or follow mains ◆ Advanced Input PFC technology, 0.99 ◆ Full protection, overload, over voltage, short circuit, over temperature etc. ◆ Adaptive load management ◆ Generator compatible ◆ RS232 communication with monitoring software, optional ◆ ...... High Frequency Three Phase Online UPS 33RYY10-60K ◆ LCD display High Frequency Double Conversion Sine Wave Online UPS 10-60KVA ◆ DSP digital control technology, zero transfer time ◆ Parallel up to 6 units for 10-40K standard type, 10/20K long backup type, 4 units for 30/40/50/60K long backup type ◆ Three phase sine wave, output power factor 1 ◆ Wide input voltage range -30% ~ +20% ◆ Wide input frequency 40-70Hz ◆ Support generator, output HZ be fixed or follow mains ◆ Three adjustable charging current 1-12A/1-16A/1-18A for different models ◆ Adjustable battery numbers ◆ ...... High Frequency Three Phase Online UPS 33RYY80-200K ◆ LCD High Frequency Double Conversion Sine Wave Online UPS 80-200KVA ◆ DSP digital control technology, zero transfer time ◆ Parallel max up to 4 units ◆ Three phase sine wave, output power factor 1 ◆ Wide input voltage range 110-300 VAC@ 50% load; 176-276VAC@ 100% load ◆ Wide input frequency 40-70Hz support generator, output HZ be fixed or follow mains ◆ Adjustable charging current ◆ Adjustable battery numbers ◆ Advanced input PFC technology, 0.99 ◆ Full protection, overload, over voltage, short circuit, over temperature etc ◆ ...... PM20 PM30 3PH Rack Module UPS PM20-30K RM ◆ Power Module 20K 30K Rack Module UPS 80/90/120/120/200/210/300KW ◆ High effciency over 94.5% at 50% load, output power factor 1 technology ◆ DSP control, online double conversion, integrated modular and parallel technology ◆ High scalability, single rack expanding 30KVA to 300KVA, N+1 or N+X redundancy in the same rack, supports 1+1 cabinet parallel operation ◆ Built-in maintenance bypass, praevia all panel control and connectors ◆ Highly reliable operation with redundant power supply(2) in STS ◆ High overload Capacity, 60mins@110%, 10mins@125%, 1mins@150% ◆ 32 to 40PCS adjustable battery numbers ◆ Adjustable charging current, Max at 8A or 6A depending on module PM50 3PH Rack Module UPS PM50K RM ◆ Power Module 50K Rack Module UPS 300K/350K/400K/500KW ◆ High effciency over 94.5% at 50% load, output power factor 1 technology ◆ DSP control, online double conversion, integrated modular and parallel technology ◆ High scalability, single rack expanding 300KVA to 500KVA ◆ N+1 or N+X redundancy in the same rack, supports 1+1 cabinet parallel operation ◆ Built-in maintenance bypass, praevia all panel control and connectors ◆ Highly reliable operation with redundant power supply in STS ◆ High overload capacity, 60mins@110%, 10mins@125%, 1mins@150% ◆ 32 to 40PCS adjustable battery numbers ◆ Adjustable charging current, Max 12A PM60 3PH Rack Module UPS PM60K RM ◆ Power Module 60K Rack Module UPS 120/180/240/300/480/600KW ◆ High effciency over 94.5% at 50% load, output power factor 1 technology ◆ DSP control, online double conversion, integrated modular and parallel technology ◆ High scalability, Single rack expanding 120KVA to 600KVA, N+1 or N+X redundancy in the same rack, supports 1+1 cabinet parallel operation ◆ Built-in maintenance bypass, praevia all panel control and connectors ◆ Highly reliable operation with redundant power supply in STS ◆ High overload capacity, 60mins@110%, 10mins@125%, 1mins@150% ◆ 32 to 40PCS adjustable battery numbers ◆ Adjustable charging current, Max 18A |